{"id":8989,"date":"2025-11-05T09:27:30","date_gmt":"2025-11-05T09:27:30","guid":{"rendered":"https:\/\/ocram-clima.com\/?p=8989"},"modified":"2025-11-13T16:53:42","modified_gmt":"2025-11-13T16:53:42","slug":"single-or-dual-flow-cmv-efficiency-consumption-and-costs","status":"publish","type":"post","link":"https:\/\/ocram-clima.com\/en\/single-or-dual-flow-cmv-efficiency-consumption-and-costs\/","title":{"rendered":"Single or Double-flow CMV: Efficiency, Consumption and Costs"},"content":{"rendered":"\n<div class=\"wp-block-rank-math-toc-block\" id=\"rank-math-toc\"><nav><ul><li class=\"\"><a href=\"#ventilacao-mecanica-controlada-vmc\">Controlled Mechanical Ventilation (CMV)<\/a><ul><li class=\"\"><a href=\"#vmc-de-simples-fluxo-funcionamento-e-limitacoes\">Single-Flow CMV: operation and limitations<\/a><\/li><li class=\"\"><a href=\"#vmc-de-duplo-fluxo-com-recuperacao-de-calor-funcionamento-e-vantagens\">Double-Flow CMV with heat recovery: operation and advantages<\/a><\/li><li class=\"\"><a href=\"#vmc-de-simples-fluxo-vs-vmc-de-duplo-fluxo\">Single-Flow CMV vs Double-Flow CMV<\/a><ul><\/ul><\/li><\/ul><\/li><li class=\"\"><a href=\"#beneficios-para-a-saude-e-bem-estar\">Health and wellbeing benefits<\/a><\/li><li class=\"\"><a href=\"#aplicacoes-praticas-da-ventilacao-de-recuperacao-de-calor\">Practical applications of heat recovery ventilation<\/a><\/li><\/ul><\/nav><\/div>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>Energy efficiency has become a priority in all human activity, and reducing our ecological footprint is imperative. At the same time, Indoor Air Quality (IAQ) is increasingly valued, not only for its influence on health and well-being, but also on the productivity of those who occupy modern buildings, from homes to offices, schools, hospitals and industrial environments.  <\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>Historically, buildings had few windows and low airtightness. In single-flow CMV systems, air was only extracted, and new air entered through window gaps or passive ventilation grilles. Today, buildings are much more insulated and brighter, an evolution that requires controlled and balanced ventilation.   <\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>This is where the dual-flow CMV system with heat recovery comes in, which not only removes polluted air, but also treats it and brings the temperature of the supplied air closer to that of the return air, combining energy efficiency, thermal comfort and clean air. <\/p>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"ventilacao-mecanica-controlada-vmc\">Controlled Mechanical Ventilation (CMV)<\/h2>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>Controlled Mechanical Ventilation is a system that ensures continuous and controlled renewal of indoor air. <\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>While natural ventilation is unpredictable, CMV maintains constant air flows, improving energy efficiency and indoor air quality. <\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>There are two main types of CMV: <\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Simple-Flow, which can extract and blow air. <\/li>\n\n\n\n<li>Double-Flow with heat recovery, which extracts and blows in new treated air, utilising the energy from the extracted air. <\/li>\n<\/ul>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"vmc-de-simples-fluxo-funcionamento-e-limitacoes\">Single-Flow CMV: operation and limitations<\/h3>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>Single-Flow systems work only by extracting stale air (kitchens, bathrooms, laundry rooms). Fresh air enters uncontrolled through cracks, windows, or intake grilles.  <\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>Although they are a more economical solution in the short term, they have several limitations: <\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Significant energy losses: hot or cold air is expelled without energy recovery, which increases the energy bill. <\/li>\n\n\n\n<li>No filtration: incoming air is neither treated nor purified. <\/li>\n\n\n\n<li>Thermal discomfort: cold draughts or temperature variations. <\/li>\n\n\n\n<li>Noise and outdoor pollution: direct entry of particles and noise. <\/li>\n\n\n\n<li>Maintenance costs: accelerated deterioration of buildings and interior spaces. <\/li>\n<\/ul>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"vmc-de-duplo-fluxo-com-recuperacao-de-calor-funcionamento-e-vantagens\">Double-Flow CMV with heat recovery: operation and advantages<\/h3>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>The Double-Flow CMV extracts stale air and blows new, treated and filtered air into the main rooms. <br>Between these two flows there is a heat exchanger that transfers up to 93% of the thermal energy from the extracted air to the new air. <\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>The result is efficient and balanced ventilation, with several advantages: <\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Superior energy efficiency, with lower heating and cooling requirements. <\/li>\n\n\n\n<li>Better indoor air quality thanks to particle and pollutant filtration. <\/li>\n\n\n\n<li>Greater thermal and acoustic comfort, without draughts. <\/li>\n\n\n\n<li>Always fresh and healthy air, ideal for homes and professional spaces. <\/li>\n<\/ul>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>In addition, modern dual-flow units can include free cooling and free heating, using outside air to naturally cool or heat the building without additional energy consumption. <\/p>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"vmc-de-simples-fluxo-vs-vmc-de-duplo-fluxo\">Single-Flow CMV vs Double-Flow CMV <\/h3>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>The difference between the two systems translates into significant differences in energy consumption and operating costs. <\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>The following simulations show the monthly energy consumption and cost associated with air conditioning, considering a flow rate of 1000m\u00b3\/h operating 8 hours\/day and a setpoint of 20\u00baC, but with two different configurations: <\/p>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"sistema-de-vmc-de-duplo-fluxo-com-recuperacao-de-calor-kt-ocra-mclima\"><strong><strong>Double-Flow Heat Recovery unit (KT OCRAMclima\u00ae) with DX coil and outdoor unit<\/strong><\/strong> <\/h4>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>Monthly graph of energy consumption and air conditioning costs, considering a heat recovery unit with 85% efficiency and electrical heater to cover the remainder if necessary. <\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"508\" src=\"https:\/\/ocram-clima.com\/wp-content\/uploads\/2025\/11\/recuperador-de-calor-1-1024x508.png\" alt=\"VMC \nCMV\" class=\"wp-image-8991\" srcset=\"https:\/\/ocram-clima.com\/wp-content\/uploads\/2025\/11\/recuperador-de-calor-1-1024x508.png 1024w, https:\/\/ocram-clima.com\/wp-content\/uploads\/2025\/11\/recuperador-de-calor-1-300x149.png 300w, https:\/\/ocram-clima.com\/wp-content\/uploads\/2025\/11\/recuperador-de-calor-1-768x381.png 768w, https:\/\/ocram-clima.com\/wp-content\/uploads\/2025\/11\/recuperador-de-calor-1-1536x762.png 1536w, https:\/\/ocram-clima.com\/wp-content\/uploads\/2025\/11\/recuperador-de-calor-1-2048x1016.png 2048w, https:\/\/ocram-clima.com\/wp-content\/uploads\/2025\/11\/recuperador-de-calor-1-500x248.png 500w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">Monthly air conditioning consumption and cost with double-flow CMV system<\/figcaption><\/figure>\n<\/div>\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>The bars represent total consumption (kWh) per month. <\/p>\n\n\n\n<p>The green line indicates the energy cost at \u20ac0.16\/kWh. <\/p>\n\n\n\n<p>The red line indicates the energy cost at \u20ac0.24\/kWh. <\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>The result shows a significant reduction in energy consumption and costs during the cold months, proving the efficiency of heat recovery in heating and cooling fresh air. <\/p>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"sistema-de-vmc-de-simples-fluxo-unidirecional-com-bateria-dx-e-unidade-exterior\"><strong>Single-Flow (unidirectional) unit with DX coil and outdoor unit<\/strong> <\/h4>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>Monthly graph of air conditioning consumption and cost, considering a single-direction unit and a DX coil with outdoor unit. <\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"508\" src=\"https:\/\/ocram-clima.com\/wp-content\/uploads\/2025\/11\/ocram-unidade-unidirecional-1024x508.png\" alt=\"CMV\nVMC\" class=\"wp-image-8968\" srcset=\"https:\/\/ocram-clima.com\/wp-content\/uploads\/2025\/11\/ocram-unidade-unidirecional-1024x508.png 1024w, https:\/\/ocram-clima.com\/wp-content\/uploads\/2025\/11\/ocram-unidade-unidirecional-300x149.png 300w, https:\/\/ocram-clima.com\/wp-content\/uploads\/2025\/11\/ocram-unidade-unidirecional-768x381.png 768w, https:\/\/ocram-clima.com\/wp-content\/uploads\/2025\/11\/ocram-unidade-unidirecional-1536x762.png 1536w, https:\/\/ocram-clima.com\/wp-content\/uploads\/2025\/11\/ocram-unidade-unidirecional-2048x1016.png 2048w, https:\/\/ocram-clima.com\/wp-content\/uploads\/2025\/11\/ocram-unidade-unidirecional-500x248.png 500w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">Monthly air conditioning consumption and cost with a Single-Flow CMV system<\/figcaption><\/figure>\n<\/div>\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>The bars represent total consumption (kWh) per month. <\/p>\n\n\n\n<p>The green line indicates the energy cost at \u20ac0.16\/kWh. <\/p>\n\n\n\n<p>The red line indicates the energy cost at \u20ac0.24\/kWh. <\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>In this scenario, energy consumption is considerably higher, especially during winter and summer, due to the absence of heat recovery; the air is heated or cooled entirely using electrical or refrigeration energy. <\/p>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"comparacao-direta\"><strong>Direct comparison<\/strong> of consumption and air conditioning costs<\/h4>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>The difference between the two systems is significant: <\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<ul class=\"wp-block-list\">\n<li>The double-flow heat recovery unit reduces energy consumption and costs by 30% to 50% compared to a single flow system. <\/li>\n\n\n\n<li>These savings translate into a rapid return on investment, as well as increased thermal comfort and better indoor air quality. <\/li>\n<\/ul>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>These results confirm that investing in double-flow ventilation with heat recovery means investing in the efficiency, sustainability and durability of the building. <\/p>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"beneficios-para-a-saude-e-bem-estar\">Health and wellbeing benefits<\/h2>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>Dual-flow CMV systems are not only notable for their energy efficiency, they are also crucial for indoor air quality (IAQ) and, consequently, for the health and comfort of those who live or work in the building. <\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>By ensuring continuous and balanced ventilation, these systems keep the air constantly refreshed, eliminating pollutants, humidity and excess carbon dioxide (CO\u2082). The result is a healthier, more stable and productive indoor environment.  <\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>Controlled mechanical ventilation provides: <\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Reduction of CO\u2082 and pollutants: prevents stale air, improves concentration and reduces symptoms associated with poor ventilation (headaches, fatigue, allergies). <\/li>\n\n\n\n<li>Greater well-being and productivity: in schools, offices and homes, clean air translates into better cognitive performance, comfort and respiratory health. <\/li>\n<\/ul>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"aplicacoes-praticas-da-ventilacao-de-recuperacao-de-calor\">Practical applications of heat recovery ventilation<\/h2>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>Heat recovery ventilation is a versatile solution that can be adapted to different types of buildings, from the residential sector to industrial environments. <\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>In all cases, the objective is the same: to ensure clean air, thermal comfort, and energy efficiency. <\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Housing and offices. Provides daily comfort and healthy air, maintaining a stable indoor temperature throughout the year. Reduces energy consumption and improves the quality of life and productivity of occupants.   <\/li>\n\n\n\n<li>Hospitals and laboratories. Essential for highly demanding environments, heat recovery systems ensure constant and controlled air renewal, limiting the spread of contaminants and ensuring health safety.  <\/li>\n\n\n\n<li>Schools and public spaces. They promote better concentration and cognitive performance, while reducing the risk of outbreaks and absenteeism associated with poor ventilation conditions.  <\/li>\n\n\n\n<li>Industry and technical environments. They adapt to specific processes, ensuring thermal stability, particle control and protection of sensitive equipment, which are essential for operational continuity and the quality of the final product.  <\/li>\n<\/ul>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"diferenciais-da-ocra-mclima-na-ventilacao-de-recuperacao-de-calor\">OCRAMclima\u00ae in heat recovery ventilation<\/h2>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>OCRAMclima\u00ae develops dual-flow controlled mechanical ventilation solutions with heat recovery, designed for efficiency, durability, and comfort. <\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>The <strong><a href=\"https:\/\/ocram-clima.com\/en\/products\/kt\/kt-home\/\">KT Home<\/a><\/strong> and <strong><a href=\"https:\/\/ocram-clima.com\/en\/products\/kt\/kt-pro\/\">KT Pro<\/a><\/strong> ranges have been designed to meet different needs, from residential spaces to buildings with higher air flow, with simple installation and optimised maintenance. <\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>Heat recovery ventilation is one of the cornerstones of energy efficiency and indoor air quality in modern buildings. <\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>With double-flow technology, it is possible to save energy, improve comfort and ensure a healthier and more sustainable indoor environment. <\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>Explore OCRAMclima\u00ae solutions and discover how <strong><a href=\"https:\/\/ocram-clima.com\/en\/products\/kt\/\">KT <\/a><\/strong>heat recovery systems can optimise energy performance and air quality.<\/p>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link has-background wp-element-button\" href=\"https:\/\/ocram-clima.com\/en\/products\/kt\/\" style=\"background-color:#7bac9c\">Learn more about<strong> KT<\/strong> heat recovery units<\/a><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button is-style-fill\"><a class=\"wp-block-button__link has-background wp-element-button\" href=\"https:\/\/ocram-clima.com\/en\/contact-form\/\" style=\"background-color:#598891\">See the OCRAMclima\u00ae product catalogue<\/a><\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Energy efficiency has become a priority in all human activity, and reducing our ecological footprint is imperative. At the same time, Indoor Air Quality (IAQ) is increasingly valued, not only for its influence on health and well-being, but also on the productivity of those who occupy modern buildings, from homes to offices, schools, hospitals and [&hellip;]<\/p>\n","protected":false},"author":7,"featured_media":8973,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[185,51],"tags":[139,153,141],"class_list":["post-8989","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-technical-articles","category-uncategorized","tag-commerce-and-services","tag-heat-recovery-unit","tag-residential-buildings"],"acf":[],"_links":{"self":[{"href":"https:\/\/ocram-clima.com\/en\/wp-json\/wp\/v2\/posts\/8989","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ocram-clima.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/ocram-clima.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/ocram-clima.com\/en\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/ocram-clima.com\/en\/wp-json\/wp\/v2\/comments?post=8989"}],"version-history":[{"count":0,"href":"https:\/\/ocram-clima.com\/en\/wp-json\/wp\/v2\/posts\/8989\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/ocram-clima.com\/en\/wp-json\/wp\/v2\/media\/8973"}],"wp:attachment":[{"href":"https:\/\/ocram-clima.com\/en\/wp-json\/wp\/v2\/media?parent=8989"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/ocram-clima.com\/en\/wp-json\/wp\/v2\/categories?post=8989"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/ocram-clima.com\/en\/wp-json\/wp\/v2\/tags?post=8989"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}